{"product_id":"johnson-pump-f4b-9-impeller-pump-oem-flange-mount-10-24967-02","title":"Johnson Pump F4B-9 Impeller Pump OEM - Flange Mount [10-24967-02]","description":" \u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eF4B-9 Impeller Pump OEM - Flange Mount\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eFlexible impeller pumps, F-series, provide an efficient solution to most raw water pumping needs. The primary advantage of a flexible impeller pump is its self-priming ability. As the vanes of the impeller are depressed and rebound, they create their own vacuum drawing fluid into the pump. A dry pump can lift the water up to as much as 3 meters. Thus a flexible impeller pump being used for engine cooling needs not to be located below the water line or manually primed. An added feature of flexible impeller pumps is that they can pass fairly large solids without clogging or damaging the pump. This reduces the need for filtering the incoming fluid. For general raw or freshwater applications, the standard long-lasting neoprene rubber impeller is used. Both the impeller and the seals depend upon the water for lubrication and will soon burn out if run dry. \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFlange mount for engines such as: Panda 12000 NE PMS Kubota, Panda 6000 ND PMS Kubota, Panda 8000 NE PMS Kubota, Panda 9000 ND PMS Kubota\u003c\/li\u003e\n\u003cli\u003eA general feature of all flexible impeller pumps is that they cannot be permitted to run dry for more than 30 seconds\u003c\/li\u003e\n\u003cli\u003eWearing parts are easily replaceable for all standard models\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEngine cooling – raw water handling\u003c\/li\u003e\n\u003cli\u003eFreshwater handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePort size: (inch) 3\/4\" hose\u003c\/li\u003e\n\u003cli\u003eMount Type: Flange\u003c\/li\u003e\n\u003cli\u003eCAM: Full 1\/1\u003c\/li\u003e\n\u003cli\u003eLip seal\u003c\/li\u003e\n\u003cli\u003eMaterial: Bronze\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCooling Capacity: \u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe required output of the cooling pump – raw water as well as fresh water handling – is related to:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEngine type: (gasoline or diesel)\u003c\/li\u003e\n\u003cli\u003eType of cooling system (size of heat exchanger)\u003c\/li\u003e\n\u003cli\u003eWater cooled engine oil, reverse gear, exhaust system\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv aria-labelledby=\"description-tab\"\u003e\u003cp\u003e*Sold as an Individual\u003c\/p\u003e\u003c\/div\u003e \u003c!--- cis2:mm5nlppq ---\u003e","brand":"Johnson Pump","offers":[{"title":"Default Title","offer_id":52566549725551,"sku":"CWR-98025","price":235.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0952\/0168\/9967\/files\/98025XL.jpg?v=1767998735","url":"https:\/\/marinetechsupplies.com\/products\/johnson-pump-f4b-9-impeller-pump-oem-flange-mount-10-24967-02","provider":"My Store","version":"1.0","type":"link"}